Legato 110 DRS (Dual Rate System) Syringe Pumps
The NEW Legato 110 Dual Rate Syringe Pump System (Legato 110 DRS) offers researchers complete flexibility to start two pumps simultaneously for delivery of two independent flow rates. The pumps are synchronized through a special input/output cable included with the system.
Product Enquiry
If you would like to send us an enquiry about this product, please click the button below, fill in the form and submit.
Product EnquiryKD Scientific Legato 110 DRS (Dual Rate System) Syringe Pumps
Two Legato® 110 Single Syringe Pumps with connection cable
The new Legato 110 Dual Rate Syringe Pump System (Legato 110 DRS) offers researchers complete flexibility to start two pumps simultaneously for delivery of two independent flow rates. The pumps communicate through a special input/output cable included with the system.
The Legato 110 DRS comes complete with two programmable infuse / withdraw syringe pumps along with an input / output communications cable to synchronously operate the pumps. This innovative syringe pump system allows the user to configure two different pumps with independent flow rates using the built in multistep programming and input / output signal communication.
All control is set through the innovative Legato touch screen user interface. No external programming or computer is required.
Both syringe pumps in the system have a wide flow rate range from 1.28 pl/min to 88.28 ml/min. Each pump can be individually set for whatever the experiment requires.
The syringe pumps are compatible with stainless steel, plastic or glass. The syringes are held in place by KD Scientific’s new clamping mechanism designed to hold the syringes securely in place. Syringe sizes from 0.5 ul to 60 ml can be used. The Legato 110 Dual Rate Syringe Pump System has an accuracy of +/-0.5% and a reproducibility of +/- 0.05%.
Features
This syringe pump system allows the user to configure two different pumps with independent flow rates using the built in multistep programming and input / output signal communication. All control is set through the innovative Legato touch screen user interface. No external computer is required.
Technical Literature
Legato 100 Series Manual |
Legato 100 Series Quick Start Guide |
KDS Legato® 110 Datasheet |
KDS Legato® Family Datasheet |
Declaration of Conformity for the Legato 100 Series Syringe Pumps |
Accuracy | ±0.5% |
Syringes (Min/Max) | 0.5 µl to 60 ml |
Flow Rate | Minimum (0.5 µl syringe): 1.28 pl/min
Maximum (10 ml syringe): 25.99 ml/min Maximum (60 ml syringe): 88.28 ml/min |
Display | 4.3 WQVGA TFT Color Display with Touchpad |
Non-Volatile Memory | Stores all Settings |
Connectors | RS485 – IEEE-1394 6 pos
USB – Type B I/O & TTL – 15 pin D-Sub Connector |
Linear Force (Max) | 13.6 kg (30 lb) @ 100% Force Selection |
Drive Motor | 0.9 Stepper Motor |
Motor Drive Control | Microprocessor with 1/16 microstepping |
Number of Microsteps per one rev.of Lead Screw |
15,360 |
Step Revolution | 0.069 µm/step |
Step Rate – Minimum | 27.5 sec/µstep |
Step Rate – Maximum | 26 usec/µstep |
Pusher Travel Rate – Minimum | 0.15 µm/min |
Pusher Travel Rate – Maximum | 159 mm/min |
Power | 100-240 VAC: 50/60 Hz, 50 W, 0.5 A fuse |
Dimensions | 22.6 x 19.05 x 15 cm (9 x 7.5 x 5 in) |
Weight | 2.66 kg (5.9 lb) |
Operating Temperature | 4 degree C to 40 degree C (40 degree F to 104 degree F) |
Storage Temperature | -10 degree C to 70 degree C (14 degree F to 158 degree F) |
Humidity | 20% to 80% RH non condensing |
Mode of Operation | Continuous |
Classification | Class 1 |
Pollution Degree | 1 |
Installation Category | 11 |
Regulatory Certification | CE, UL, CSA, CB Scheme, EU RoHS |