Filaments and Accessories for Pipette Pullers

Box filaments are recommended for large diameter, double barreled, or aluminosilicate glass. Box filaments are particularly suitable for slice preparations where long, parallel walls would aid penetration. If using a box filament, the size of the square box should be approximately 1.0mm to 1.5mm larger than the outside diameter of the glass that you will be using. For IVF and ICSI applications, a 2.5mm x 4.5mm box filament is recommended. For pronuclear injection work, we recommend a 2.5mm x 2.5mm box filament. Call for more specific advice or to request a combination of settings, filaments, and glass for your application. Trough filaments are excellent general purpose filaments and are recommended for patch pipettes produced from either standard or thin wall glass.

Product Enquiry

If you would like to send us an enquiry about this product, please click the button below, fill in the form and submit.

Product Enquiry

Product Enquiry

Please fill out the form if you would like to enquire about this product.

"*" indicates required fields

Name
Please indicate the name of your University or company
We would really like to stay in touch, so that we can inform you about new products, training events and other news that we think might be of interest to you. To comply with data protection regulations, we can only contact you in this way if we have your explicit permission to do so. By ticking the opt in box you are giving consent for Linton Instrumentation to process your data and you understand that you have the right to withdraw it at any time.*

Filaments and Accessories for Pipette Pullers

Filaments

(Minimum purchase of filaments is 4)

Appropriate filament selection depends on your research application, but a general guideline for filaments is as follows:

Box Filament
Box Filament

Box Filaments – Recommended for small to large diameter borosilicate glass, double barreled, or aluminosilicate glass. Box filaments are particularly suitable for patch pipettes, slice preparations, and for sharp electrodes and microinjection pipettes where gradual parallel walls would aid cell penetration. When using a box filament, the size of the square box should be approximately 1.0mm to 1.5mm larger than the outside diameter of the glass that you will be using.

For IVF and ICSI applications, a 2.5mm x 4.5mm box filament (FB245B) is recommended. For pronuclear injection work, we recommend a 2.5 mm x 2.5 mm box filament (FB255B). Call for more specific advice or to request a combination of settings, filaments, and glass for your application.

 

 

Trough Filament
Trough Filament

Trough Filaments – Excellent general purpose filaments and are recommended for creating longer slice patch pipettes and sharp electrodes. The trough filament is not ideal for making patch pipettes or when using glass over 1.2 mm OD. If very short tapers are required for patch electrodes or for microinjection, a 2.5 mm or 3 mm box filament is recommended.

 

 

Custom Filaments – A custom filament can be created if your pipette needs can not be met by one of the standard box or trough filaments. Please call Sutter for details.

Sutter pre-programs the P-97 with a 2.5 mm x 2.5 mm box filament unless an alternative filament is requested.

For either shape of filament (box or trough), increasing the filament width tends to increase the length of the pipette taper. If there are specific questions as to the sizes needed, please call and our technical support staff will guide you in your choice.

Ordering Information

 

Box Filaments
Catalog Number Description
FB215B 2.0 mm square box filament, 1.5 mm wide
FB220B 2.0 mm square box filament, 2.0 mm wide
FB230B 2.0 mm square box filament, 3.0 mm wide
FB255B 2.5 mm square box filament, 2.5 mm wide
FB245B1 2.5 mm square box filament, 4.5 mm wide
FB315B 3.0 mm square box filament, 1.5 mm wide
FB320B 3.0 mm square box filament, 2.0 mm wide
FB330B 3.0 mm square box filament, 3.0 mm wide
Trough Filaments
Catalog Number Description
FT315B 1.5 mm wide trough filament
FT320B 2.0 mm wide trough filament
FT330B 3.0 mm wide trough filament
FT345B 4.5 mm wide trough filament
Custom Filaments
Catalog Number Description
FILAMENT Custom platinum/iridium filament (Phone Sutter for details)
P-30 Filaments
Catalog Number Description
PF30T15 1.5 mm wide trough filament
PF30T20 2.0 mm wide trough filament
PF30T30 3.0 mm wide trough filament
PF30N2 Nichrome filament – 3 turns (BEFORE SN# P30-680)
PF30N-42 Nichrome filament – 4 turns (AFTER SN# P30-679)
Nichrome Filament
Nichrome Filament
P-77A Loop Filaments
Catalog Number Description
(SN# 160 and greater)
FL315A 3.0 mm loop filament, 1.5 mm wide
FL320A 3.0 mm loop filament, 2.0 mm wide
FL325A 3.0 mm loop filament, 2.5 mm wide
(SN# less than 160)
FL315X 3.0 mm loop filament, 1.5 mm wide
FL320X 3.0 mm loop filament, 2.0 mm wide
FL325X 3.0 mm loop filament, 2.5 mm wide

 

Loop Filament
Loop Filament

Accessories

Catalog Number Description
FPS Fire polishing spacer for P-97, P-87, P-2000 pullers
FS1875 Platinum/iridium sheet, 18 mm x 75 mm x 0.05 mm (0.002 in)
CTS Ceramic tile for scoring glass
BX10 Pipette storage box – Holds 10 (4 3/4 x 3 5/8 x 3/4 in)
BX20 Pipette storage box – Holds 20 (7 x 3 5/8 x 3/4 in)

1 For P-87, please contact Sutter
2 P-30/N pullers (serial number lower than P-30-680) came with a P30N filament installed. You can now select either the P30N or P30N-4 filament. With the P30N-4 you can 1) use lower heat settings, 2) pull longer tapers (2-3cm) and 3) use aluminosilicate glass. If you need to pull very short tapers, the P30N is recommended.

Fire Polishing Spacer
Fire Polishing Spacer
Ceramic tile for scoring glass
Ceramic tile for scoring glass
Pipette storage box
Pipette storage box

 

 

 

 

 

You may also like…