CODA® High Throughput System

Multiple animal noninvasive blood pressure system

The CODA® mouse rat tail-cuff system was designed to allow accurate blood pressure measurement in mice and rats. Blood pressure is measured in the tail of the mouse or rat using Volume Pressure Recording (VPR) sensor technology. The included software allows you to continuously view data in real-time.

Product Enquiry

If you would like to send us an enquiry about this product, please click the button below, fill in the form and submit.

Product Enquiry

Product Enquiry

Please fill out the form if you would like to enquire about this product.

"*" indicates required fields

Name
Please indicate the name of your University or company
We would really like to stay in touch, so that we can inform you about new products, training events and other news that we think might be of interest to you. To comply with data protection regulations, we can only contact you in this way if we have your explicit permission to do so. By ticking the opt in box you are giving consent for Linton Instrumentation to process your data and you understand that you have the right to withdraw it at any time.*
Product code Channels
CODA-HT2 CODA High Throughput System with 2 Activated Channels
CODA-HT4 CODA High Throughput System with 4 Activated Channels
CODA-HT6 CODA High Throughput System with 6 Activated Channels
CODA-HT8 CODA High Throughput System with 8 Activated Channels

 

Features & Benefits

  • Multifunctional Monitoring Capability
  • Measures systolic, diastolic, and mean blood pressure as well as heart rate, tail blood volume and blood flow
  • Extremely Accurate
  • Diastolic blood pressure is measured, not just calculated
  • For Mice and Rats
  • Measures mice and rats as small as 8 grams and as large as 950 grams
  • High Sensitivity
  • Measures dark-skinned mice (C57BL/6) without difficulty
  • Versatile Application
  • Measures awake or anesthetized animals with equal accuracy, consistency, and reliability
  • MRI Compatible
  • Able to measure anesthetized animals in a radiological environment
  • High Throughput Capability
  • Connect up to 6 high throughput controllers to measure up to 48 animals

 

System Includes

  • NIBP controller
  • Database software
  • Far infrared warming platform(s)
  • Animal holder, one for each channel (*size to be defined at time of order)
  • VPR sensor and occlusion cuff kit, one for each channel (*size to be defined at time of order)
  • Infrared thermometer
  • Cardiovascular Genomics textbook
  • Product manual
  • 1-Year 100% Parts & Labor Warranty (Extended 2-Year Warranty available)

 

With the CODA®, You Can Measure:

  • 6 blood pressure parameters: systolic, diastolic, and mean BP, heart rate, tail blood volume and blood flow
  • Mice as small as 8 grams to rats as large as 950 grams
  • Diastolic blood pressure measured, not just a calculated value
  • Dark-skinned mice (C57BL/6) without difficulty
  • Awake or anesthetized animals with equal accuracy, consistency, and reliability
  • Anesthetized animals in a radiological environment (MRI compatibility)

 

See How the Noninvasive Tail-Cuff System Works

The animal nose cone holders that accompany the CODA system were specifically designed for noninvasive tail blood pressure measurements. The clear acrylic holders provide unrestricted breathing and allow complete visibility to the researcher.

The VPR sensor incorporates a specially designed differential pressure transducer that measures the systolic and diastolic blood pressure by determining the blood volume in the tail. We have cuff sizes for mice as small as 8 grams to rats as large as 950 grams.

 

About Volume Pressure Recording (VPR)?

VPR is a clinically validated method to measure blood pressure in mice and rats by determining the tail blood volume using a volume pressure recording sensor and an occlusion tail-cuff. VPR provides 99% correlation with telemetry and direct blood pressure measurements. Only our VPR technology can actually measure the diastolic blood pressure; all other tail-cuff technologies estimate (calculate) the diastolic blood pressure in mice and rats.

 


Support Documents

Animal Stress Level Evaluation
Clinical Bibliographies
CODA High Throughput Manual
CODA Noninvasive Pressure Systems Brochure
CODA Publications
Noninvasive Blood Pressure Publications
VPR Validation Study