Fast-response needle probes for instant readings in tissue, semi-solids,liquids. Also for very small specimens, powders and materials

Product Enquiry

If you would like to send us an enquiry about this product, please click the button below, fill in the form and submit.

Product Enquiry

Product Enquiry

Please fill out the form if you would like to enquire about this product.

"*" indicates required fields

Name
Please indicate the name of your University or company
We would really like to stay in touch, so that we can inform you about new products, training events and other news that we think might be of interest to you. To comply with data protection regulations, we can only contact you in this way if we have your explicit permission to do so. By ticking the opt in box you are giving consent for Linton Instrumentation to process your data and you understand that you have the right to withdraw it at any time.*

Please note the following definitions in the product descriptions below:

Time Constant is defined as the time required to reach 63% of final temperature in liquid. An accurate reading is obtained when the reading stops changing, typically 5-10 time constants.

Maximum Temperature refers to intermittent use of probe. When probe is used for continuous measurements, maximum temperature should be reduced by 25% unless specified.

 

Needle Microprobes

Fast-response needle probes for instant readings in tissue, semisolids and liquids. Also suitable for very small specimens, powders and materials.

The needle tip is sealed to ensure only stainless steel contacts the specimen. Sensors are accurate to ±0.1°C in the physiological range and have a maximum temperature of 200°C. Each sensor is fitted with a 5 ft. lead.

Probes are available in a range of needle gauges and lengths. The smallest microprobes (narrow gauge) give fastest reading. Short probes are easier to insert and last longer. Type #’s indicate needle gauge and needle length in cm (eg MT-29/1HT is a 29 gauge needle of  length 1cm). An HT extension indicates the autoclavable version.

MT probe sizing

 

Sizes Available (ga/cm.):

Gauge Sensors Time constant
29 ga (0.013”) MT-29/1, MT-29/2, MT-29/3, MT-29/5 0.025s
26ga (0.018”) MT-26/2, MT-26/4, MT-26/6 0.1s
23ga (0.025” MT-23/3, MT-23/5, MT-23/8 0.15s

All needle probes are non-isolated. Isolated versions of 23 ga. and larger needles are available for special order.


MT-4 Needle Microprobe

Similar to MT-29/1 but has blunt tip. Good for instant skin and surface temperatures as well as liquids. The MT-4 has a time constant of 0.025 secs and is not isolated.

Sensor Tip Diameter 29 ga. (.013”) Blunt tip
Accuracy ±0.1°C in the physiological range
Time Constant: 0.025 seconds
Maximum Temperature: 200°C
Minimum Temperature -50°C
Lead Length 5 feet
Sterilization Protocol Gas ETO, Gluteraldehyde, Isoprophyl Alcohol(can be custom made to be autoclaveable)

MT-D Needle Microprobe

Fast-responding, sealed blunt tip surface probe. Ideal for dental application for locating inflammation.

Sensor Tip Diameter 29 ga. (.013”)
Accuracy ±0.1°C in the physiological range
Time Constant: 0.025 seconds
Maximum Temperature: 200°C
Minimum Temperature -50°C
Lead Length 5 feet
Sterilization Protocol Gas ETO, Gluteraldehyde, Isoprophyl Alcohol(can be custom made to be autoclaveable)

MT-D Needle MicroprobeMT-D dimensions

 

 

 


ICT-4 Micro-Surface Microprobe

Micro-Surface Microprobe ideal for temperature measurements of integrated circuits and other micro specimens with 0.1°C accuracy.

0.5” straight stainless steel shaft with slightly protruding sensor bead to facilitate temperature probing. 5” tubular handle fits micro-manipulators. Maximum temperature 200°C (intermittent) or 100°C for continuous use.

Sensor Tip Diameter .013”
Accuracy ±0.1°C in the physiological range
Time Constant: 0.025 seconds
Maximum Temperature: 200°C
Minimum Temperature -50°C
Lead Length 5 feet
Sterilization Protocol Gas ETO, Gluteraldehyde, Isoprophyl Alcohol