CMA 402 Syringe Pump
The CMA 402 Syringe Pump is a compact, flexible, dual syringe pump designed for low pulse-free flow rates suitable for microdialysis experiments and other low flow experiments. Start/Stop and flow rate can be set individually for each syringe.
The pump is precalibrated for 1, 2.5 or 5 mL syringes with flow rates between 0.1 µL/min and 20 µL/min. The flow rates are shown on the LED displays. The CMA 402 Microdialysis Pump is even more flexible when controlled by a computer through the RS-232 interface.
Product Enquiry
If you would like to send us an enquiry about this product, please click the button below, fill in the form and submit.
Product Enquiry
CMA 402 Syringe Pump
The CMA 402 Microdialysis Syringe Pump is a compact, flexible, dual syringe pump designed for low pulse-free flow rates suitable for microdialysis experiments and other low flow experiments.
- Dual syringes independently controlled
- Flow rates from 0.1 – 20 µL/min
- Independent flow directions to infuse or withdraw
Start/Stop and flow rate can be set individually for each syringe. The pump is precalibrated for 1, 2.5 or 5 mL syringes with flow rates between 0.1 µL/min and 20 µL/min. The flow rates are shown on the LED displays. The CMA 402 Microdialysis Pump is even more flexible when controlled by a computer through the RS-232 interface. For instance, a preset volume can easily be set. A flush feature fills the system at a flow rate of 25 µL/min.
The CMA 402 is available in two different versions, one of which includes accessories such as vial holders and probe clips, allowing easier handling of the microdialysis probe.
Ordering information
Product Name | Item # |
CMA 402 Microdialysis Syringe Pump with Accessory Kit | CMA8003100 |
CMA 402 Microdialysis Syringe Pump | CMA8003110 |
USB Cable for CMA 402, Type A-B | CMA8002773 |
Journal Articles
Deding Liu, Shuogui Xu, Heping Xiao, Zhuo Wang, Ningfang Mao, Jia Zhou, Rui Liu & Yi Huang (2014) Quantitative determination of unbound levofloxacin by simultaneous microdialysis in rat pancreas after intravenous and oral doses Journal of Pharmacy and Pharmacology
Lisa Amanda Holm Rottbøll, Kerstin Skovgaard, Kristiane Barington, Henrik Elvang Jensen & Christian Friis (2015 ) Intrabronchial Microdialysis: Effects of Probe Localization on Tissue Trauma and Drug Penetration into the Pulmonary Epithelial Lining Fluid Basic & Clinical Pharmacology & Toxicology
Teayoun Kim, John F. Moore, Jon D Sharer, Kevin Yang, Philip A Wood & Qinglin Yang (2014 ) Carnitine Palmitoyltransferase 1b Deficient Mice Develop Severe Insulin Resistance After Prolonged High Fat Feeding Journal of Diabetes & Metabolism
Jingjing Wei, Limei Yao, Lei Yang, Wei Zhao, Si Shia, Qingyan Cai, Dingsheng Chen, Weirong Li & Qi Wang (2015 ) Alteration of glutamate/GABA balance during acute alcohol intoxication in rats: Effect of Xingnaojing injection Journal of Ethnopharmacology
Yanping Cun, Lin Tang, Jie Yan, Chao He, Yang Li, Zhian Hu & Jianxia Xia (2014 ) Orexin A attenuates the sleep-promoting effect of adenosine in the lateral hypothalamus of rats Neuroscience Bulletin
Accuracy | ±1.5% |
Calibration | Precalibrated |
Certifications | CE |
Computer Connection | RS232 and USB |
Dimensions (W x D x H) | 207 x 135 x 48 mm |
Display | 2-digit LED display showing flow rate or syringe size |
External Connections | Variable |
Fast Feed | Approx. 20 |