Legato 110 DRS (Dual Rate System) Syringe Pumps

The NEW Legato 110 Dual Rate Syringe Pump System (Legato 110 DRS) offers researchers complete flexibility to start two pumps simultaneously for delivery of two independent flow rates. The pumps are synchronized through a special input/output cable included with the system.

Product Enquiry

If you would like to send us an enquiry about this product, please click the button below, fill in the form and submit.

Product Enquiry

Product Enquiry

Please fill out the form if you would like to enquire about this product.

"*" indicates required fields

Name
Please indicate the name of your University or company
We would really like to stay in touch, so that we can inform you about new products, training events and other news that we think might be of interest to you. To comply with data protection regulations, we can only contact you in this way if we have your explicit permission to do so. By ticking the opt in box you are giving consent for Linton Instrumentation to process your data and you understand that you have the right to withdraw it at any time.*
KD Scientific logo

KD Scientific Legato 110 DRS (Dual Rate System) Syringe Pumps


Two Legato® 110 Single Syringe Pumps with connection cable

The new Legato 110 Dual Rate Syringe Pump System (Legato 110 DRS) offers researchers complete flexibility to start two pumps simultaneously for delivery of two independent flow rates. The pumps communicate through a special input/output cable included with the system.

The Legato 110 DRS comes complete with two programmable infuse / withdraw syringe pumps along with an input / output communications cable to synchronously operate the pumps. This innovative syringe pump system allows the user to configure two different pumps with independent flow rates using the built in multistep programming and input / output signal communication.

All control is set through the innovative Legato touch screen user interface. No external programming or computer is required.

Both syringe pumps in the system have a wide flow rate range from 1.28 pl/min to 88.28 ml/min. Each pump can be individually set for whatever the experiment requires.

The syringe pumps are compatible with stainless steel, plastic or glass. The syringes are held in place by KD Scientific’s new clamping mechanism designed to hold the syringes securely in place. Syringe sizes from 0.5 ul to 60 ml can be used. The Legato 110 Dual Rate Syringe Pump System has an accuracy of +/-0.5% and a reproducibility of +/- 0.05%.

Features

This syringe pump system allows the user to configure two different pumps with independent flow rates using the built in multistep programming and input / output signal communication. All control is set through the innovative Legato touch screen user interface. No external computer is required.

Technical Literature

Legato 100 Series Manual
Legato 100 Series Quick Start Guide
KDS Legato® 110 Datasheet
KDS Legato® Family Datasheet
Declaration of Conformity for the Legato 100 Series Syringe Pumps
Accuracy ±0.5%
Syringes (Min/Max) 0.5 µl to 60 ml
Flow Rate Minimum (0.5 µl syringe): 1.28 pl/min

Maximum (10 ml syringe): 25.99 ml/min

Maximum (60 ml syringe): 88.28 ml/min

Display 4.3 WQVGA TFT Color Display with Touchpad
Non-Volatile Memory Stores all Settings
Connectors RS485 – IEEE-1394 6 pos

USB – Type B

I/O & TTL – 15 pin D-Sub Connector

Linear Force (Max) 13.6 kg (30 lb) @ 100% Force Selection
Drive Motor 0.9 Stepper Motor
Motor Drive Control Microprocessor with 1/16 microstepping
Number of Microsteps
per one rev.of Lead Screw
15,360
Step Revolution 0.069 µm/step
Step Rate – Minimum 27.5 sec/µstep
Step Rate – Maximum 26 usec/µstep
Pusher Travel Rate – Minimum 0.15 µm/min
Pusher Travel Rate – Maximum 159 mm/min
Power 100-240 VAC: 50/60 Hz, 50 W, 0.5 A fuse
Dimensions 22.6 x 19.05 x 15 cm (9 x 7.5 x 5 in)
Weight 2.66 kg (5.9 lb)
Operating Temperature 4 degree C to 40 degree C (40 degree F to 104 degree F)
Storage Temperature -10 degree C to 70 degree C (14 degree F to 158 degree F)
Humidity 20% to 80% RH non condensing
Mode of Operation Continuous
Classification Class 1
Pollution Degree 1
Installation Category 11
Regulatory Certification CE, UL, CSA, CB Scheme, EU RoHS