We would really like to stay in touch, so that we can inform you about new products, training events and other news that we think might be of interest to you. To comply with data protection regulations, we can only contact you in this way if we have your explicit permission to do so. By ticking the opt in box you are giving consent for Linton Instrumentation to process your data and you understand that you have the right to withdraw it at any time.*

OxyStar-100 O2 Monitor

The OxyStar-100 is a fast-response, high accuracy oxygen analyzer for respiratory monitoring, hypoxic gas studies, or general laboratory use. It features a measurement range of 0 – 100% O2, with a resolution of 0.1%. Sample flow is adjustable over a 10 – 200ml/min range, making respiratory oxygen measurements possible on small as well as larger animals and human subjects.

The instrument uses an advanced paramagnetic oxygen transducer with fully digital operation. Calibration is accomplished with a simple two-point procedure, typically nitrogen (for 0.0%) and room air (20.9%). The analyzer offers excellent linearity and stability over its entire measurement range.

Standard features of the OxyStar-100 include simple one-knob calibration, analog voltage output signal, and a serial data output for remote monitoring or data collection. A bar-graph display shows rapid changes and trends over three user-selectable ranges. Sample inlet and outlet connections use standard Luer-loc fittings. The instrument comes complete with sample tubing and an accessory pack of tubing and adapter fittings for constructing custom sample tubing configurations.
SpecificationsMeasurement range 0 – 100% O2
Intrinsic accuracy <+0.15% O2
Linearity over full measurement range <+0.1% O2
Measurement resolution 0.1% O2
Repeatability <+0.1% O2
Zero drift <+0.2% O2 / month
Response time (21% O2 – 16% O2) <330mS @ 150ml/min
Transducer technology Paramagnetic
OUTPUT voltage range 0 – 10.0V
OUTPUT connector BNC
SERIAL OUTPUT protocol 2400,N,8,1
SERIAL OUTPUT connector 9-pin D-SUB female
SAMPLE INLET / OUTLET connectors Luer-loc female
Power requirements (using supplied power adapter) 115/230V, 50/60Hz @ 5VA
Dimensions 9.3W x 2.5H x 8.0D inches (23.6 x 6.4 x 20.3 cm)

Ordering Information

14-11000 OxyStar-100 Oxygen monitor Respiratory monitoring, hypoxic gas measurement
11-10000 CapStar-100 Carbon Dioxide monitor Respiratory monitoring, metabolic measurement
15-10000 MicroCapStar Micro-sampling CO2 monitor CO2 monitoring in mice and other small animals.